Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

AS/NZS 1972:2006 Cables Location:Home> > English > Product Center > Mining Cables > AS/NZS 1972:2006 Cables >

Type 2S 1.1/1.1KV Collectively Screened

Article source:http://www.trcables.com/   author:上海嗨润   Release time:2018-02-02 14:43   Browse times:second

Type 2S 1.1/1.1KV Collectively Screened

Applications

These collectively copper screened cables are used for wiring of machines or between machines and equipment wherea rubber cable is desired. These cables are also used for longwall lighting circuits, and may contain pilot and controlcores or twisted pair and screened cores.

Standards

Type 2S 1.1/1.1KV & 3.3/3.3KV Collectively Screened

AS/NZS 1972:2006

AS/NZS 1125

AS/NZS 3808

Construction

Conductors: Stranded tinned annealed copper conductor.

Insulation: EPR.

Filling: Elastomer centre filler.

Bedding: Polyester tape.

Composite Screen (earth conductor): Tinned annealed copper braiding interwove with polyester yarn.

Sheath: Heavy duty CPE sheath

Dimensions and Weight

Number of Core Nominal Conductor Area Strand Size Insulation Thickness Core screen Nominal Sheath Thickness Nominal Overall Diameter Nominal Weight
Strand Size Area of Screen
  mm² No/mm mm mm mm² mm mm kg/100m
Type 2S 1.1/1kV Collectively Screened
2 1.5 30/0.25 1.0 0.20 5.3 1.8 14.7 17
4 1.5 30/0.25 1.0 0.20 12.1 1.8 19.9 26
6 1.5 30/0.25 1.0 0.20 22.6 1.8 25.7 35
16 1.5 30/0.25 1.0 0.25 113.1 1.8 47.1 71
20 1.5 30/0.25 1.0 0.25 159.0 1.8 53.2 82